Effect of gap dimension on wear resistance of luting agents.

Koichi Shinkai, Shiro Suzuki, Leinfelder Kf, Yoshiroh Katoh

PubMed · 1995 · 35 citations · 0 references

Concepts

Abstract

PURPOSE: To examine the correlation between horizontal gap width and wear depth of luting resin cements and a glass ionomer used with resin composite inlays. MATERIALS AND METHODS: A cylindrical cavity (4 x 3 mm) was made on the occlusal surface of molars. Four specimens were prepared for each luting agent. The samples were subjected to a three-body wear test for 400,000 cycles. The wear values of both composite and luting agents were determined by profilometric tracings to the nearest 2 micrometers. The relationship between gap width and wear depth was confirmed by linear regression analysis. RESULTS: Significant relationships existed amongst gap width, cement wear and type of cement. The effects were considerably less pronounced with microfilled cements.