Biventricular Circulatory Support Using 2 Axial Flow Catheters for Cardiogenic Shock Without the Need for Surgical Vascular Access
22
Citations
4
References
2016
Year
Assisted CirculationPercutaneous Coronary InterventionCardiogenic ShockCardiac AnaesthesiaCardiovascular DiseaseBiventricular Circulatory SupportPatient SafetyVascular SurgeryMechanical Circulatory SupportDenofrio DVascular AccessAxial Flow CathetersMedicineCardiologyEmergency MedicineAnesthesiology
HomeCirculation: Cardiovascular InterventionsVol. 9, No. 6Biventricular Circulatory Support Using 2 Axial Flow Catheters for Cardiogenic Shock Without the Need for Surgical Vascular Access Free AccessResearch ArticlePDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissionsDownload Articles + Supplements ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toSupplemental MaterialFree AccessResearch ArticlePDF/EPUBBiventricular Circulatory Support Using 2 Axial Flow Catheters for Cardiogenic Shock Without the Need for Surgical Vascular Access Nima Aghili, MD, Yousef Bader, MD, Amanda R. Vest, MD, Michael S. Kiernan, MD, Carey Kimmelstiel, MD, David DeNofrio, MD and Navin K. Kapur, MD Nima AghiliNima Aghili From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. , Yousef BaderYousef Bader From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. , Amanda R. VestAmanda R. Vest From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. , Michael S. KiernanMichael S. Kiernan From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. , Carey KimmelstielCarey Kimmelstiel From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. , David DeNofrioDavid DeNofrio From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. and Navin K. KapurNavin K. Kapur From the Department of Medicine, Cardiovascular Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA. Originally published17 May 2016https://doi.org/10.1161/CIRCINTERVENTIONS.116.003636Circulation: Cardiovascular Interventions. 2016;9:e003636IntroductionBiventricular failure in cardiogenic shock remains a major clinical problem. Use of percutaneously delivered, acute circulatory support devices for cardiogenic shock has grown exponentially due in large part to increasing global familiarity and clinical experience demonstrating hemodynamic efficacy of these devices.1 Until recently, percutaneous support options for biventricular failure have been limited to venoarterial extracorporeal membrane oxygenation or biventricular centrifugal flow pumps. We recently reported the first use of biventricular axial flow catheters with the Impella 5.0 and RP (Abiomed Inc) systems, which required surgical vascular access for the 5.0 implant.2 We now report the first patient with cardiogenic shock receiving biventricular support using the Impella CP and RP catheters (BiPella) without the need for surgical vascular access.A 30-year-old woman presented with hypotension and dyspnea after 1 week of a fever and lethargy. Within 24 hours of admission, hemodynamics demonstrated biventricular failure and an echocardiogram showed a left ventricular ejection fraction of 10% and severely dilated right ventricle (RV), despite treatment with an intra-aortic balloon pump, dobutamine, and norepinephrine (Table; Movie I in the Data Supplement). Endomyocardial biopsy confirmed the diagnosis of fulminant lymphocytic myocarditis, and pulse steroids were initiated without hemodynamic improvement. A multidisciplinary discussion determined that the patient was a potential candidate for orthotopic heart transplantation if myocardial recovery was not achieved. Durable mechanical circulatory support was deferred because of clinical instability with impaired end-organ function and uncertainty about committing the patient to surgical biventricular devices. Nondurable mechanical circulatory support using venoarterial extracorporeal membrane oxygenation was considered; however, her oxygenation status was stable, and this strategy would limit our ability to independently assess RV or left ventricle recovery and de-escalate support in a stepwise manner. We elected to proceed with simultaneous biventricular axial flow catheter support using the Impella CP and Impella RP (Abiomed Inc, Danvers, MA) devices.Table. Hemodynamic and Metabolic ParametersHemodynamic and Metabolic ParametersIABP+Dobutamine+Levophed3 h on BiPella+Dobutamine72 h on BiPellaRA pressure, mm Hg23186PA pressure, mm Hg33/2340/2828/12PCWP, mm Hg192010Cardiac index, L/min per m21.32.52.8PA saturation, %396369FA saturation, %999999MAP, mm Hg587268RA:PCWP ratio1.20.90.6PAPi0.40.72.7Creatinine, mg/dL0.83.391.9Lactate, mEq/dL4.271.5AST, IU/L187111 282841Total bilirubin, IU/L0.92.71.1Lactate dehydrogenase, IU/dL34391147552100Troponin-I, ng/mL13n/an/aAST indicates aspartate aminotransferase; FA, femoral artery; IABP, intra-aortic balloon pump; MAP, mean arterial pressure; PA, pulmonary artery; PAPi, pulmonary artery pulsatility index; PCWP, pulmonary capillary wedge pressure ratio; and RA, right artery.The Impella CP device was deployed into the left ventricle via a 14Fr sheath in the right femoral artery, maximally activated at P8, and achieved 3.4 L/min of flow. Within minutes of device activation, mean right atrial (RA) pressure increased from 25 to 45 mm Hg, whereas mean pulmonary artery pressure remained unchanged (Figure 1A). An echocardiogram confirmed RV overload and moderate to severe tricuspid regurgitation. We then rapidly deployed the Impella RP into the RV via a 23Fr sheath in the right femoral vein. Flow through the RP device was titrated to P6, which matched CP flows at 3.4 L/min. Within minutes of activation, mean RA pressure was reduced to 18 mmHg and aortic pressure improved (Figure 1B). The intra-aortic balloon pump was removed after RP activation. Within 3 hours after BiPella support, cardiac index improved to 2.5 and levophed was weaned off. After 72 hours of BiPella support, indices of RV failure including RA pressure, RA:pulmonary capillary wedge pressure ratio (RA:PCWP), and the pulmonary artery pulsatility index (PAPi) had normalized.3 The RP was explanted at the bedside with manual compression, followed by removal of the CP device 6 hours later once stability of hemodynamic parameters was confirmed. The patient was ambulatory within 24 hours after BiPella explantation and was discharged from hospital on day 8. At 6 months of follow-up, her left ventricular ejection fraction was 50% with normal RV size and function (Movie II in the Data Supplement).Download figureDownload PowerPointFigure 1. Hemodynamic tracings of right atrial (RA), pulmonary artery (PA), and aortic (Ao) pressures. A, Activation of the Impella CP device increases RA pressure without changing PA or Ao pressures. B, Activation of the Impella RP device with ongoing CP support reduces RA pressure, narrows the PA pulse pressure, and increases mean Ao pressure.DiscussionPercutaneously delivered biventricular support has evolved considerably during the past 5 years and until now has required one of the following: (1) a trans-septal puncture for biventricular TandemHeart support, (2) surgical vascular access for insertion of an Impella 5.0 combined with either a TandemHeart RV support device4 or Impella RP,2 or (3) use of an oxygenator with venoarterial extracorporeal membrane oxygenation. We now report the first case of biventricular failure supported with the Impella CP and RP axial-flow catheters without the need for surgical vascular access or trans-septal puncture (Figure 2). This case demonstrates that: (1) nonsurgical, implantation, and removal of percutaneous biventricular axial-flow catheters is feasible; (2) Bipella improve hemodynamic indices in the setting of cardiogenic shock; (3) close monitoring of intraprocedural hemodynamics using 3 transducers (RA, pulmonary artery, and aortic pressures) may identify when RV support is required; and (4) biventricular support combined with immunosuppressive therapy may lead to myocardial recovery in the setting of myocarditis. Major advantages of the Bi-Pella approach include the ability to explant one device at a time in a step-wise manner to monitor the need for ongoing univentricular or biventricular support and early ambulation after BiPella removal. These findings suggest that Bipella is a feasible nonsurgical approach for biventricular failure, especially among patients who are poor or unclear candidates for durable mechanical circulatory support.Download figureDownload PowerPointFigure 2. A, A fluoroscopic image showing the Bipella configuration using an Impella CP and Impella RP axial flow catheters. B, Histological slide showing fulminant lymphocytic myocarditis.DisclosuresDr Kapur receives research support and speaker honoraria from Abiomed and Maquet. Dr Kiernan receives consulting fees and speaker honoraria from Heartware and Thoratec. The other authors report no conflicts.FootnotesThe Data Supplement is available at http://circinterventions.ahajournals.org/lookup/suppl/doi:10.1161/CIRCINTERVENTIONS.116.003636/-/DC1.Correspondence to Navin K. Kapur, MD, The Cardiovascular Center, Tufts Medical Center, 800 Washington St, Box No. 80, Boston, MA 02111. E-mail [email protected]References1. Rihal CS, Naidu SS, Givertz MM, Szeto WY, Burke JA, Kapur NK, Kern M, Garratt KN, Goldstein JA, Dimas V, Tu T; Society for Cardiovascular Angiography and Interventions (SCAI); Heart Failure Society of America (HFSA); Society of Thoracic Surgeons (STS); American Heart Association (AHA), and American College of Cardiology (ACC). 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care: Endorsed by the American Heart Assocation, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d'Intervention.J Am Coll Cardiol. 2015; 65:e7–e26. doi: 10.1016/j.jacc.2015.03.036.CrossrefMedlineGoogle Scholar2. Kapur NK, Jumean M, Ghuloom A, Aghili N, Vassallo C, Kiernan MS, DeNofrio D, Pham DT.First successful use of 2 axial flow catheters for percutaneous biventricular circulatory support as a bridge to a durable left ventricular assist device.Circ Heart Fail. 2015; 8:1006–1008. doi: 10.1161/CIRCHEARTFAILURE.115.002374.LinkGoogle Scholar3. Korabathina R, Heffernan KS, Paruchuri V, Patel AR, Mudd JO, Prutkin JM, Orr NM, Weintraub A, Kimmelstiel CD, Kapur NK.The pulmonary artery pulsatility index identifies severe right ventricular dysfunction in acute inferior myocardial infarction.Catheter Cardiovasc Interv. 2012; 80:593–600. doi: 10.1002/ccd.23309.CrossrefMedlineGoogle Scholar4. Nagy CD, Jumean MF, Pham DT, Kiernan MS, Denofrio D, Kapur NK.Percutaneous circulatory support for biventricular failure.Circ Cardiovasc Interv. 2013; 6:e12–e14. doi: 10.1161/CIRCINTERVENTIONS.112.000018.LinkGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Kuroda T, Miyagi C, Fukamachi K and Karimov J (2023) Biventricular assist devices and total artificial heart: Strategies and outcomes, Frontiers in Cardiovascular Medicine, 10.3389/fcvm.2022.972132, 9 Alkhunaizi F, Burkhoff D and Brener M (2022) Right-Sided Mechanical Circulatory Support – A Hemodynamic Perspective, Current Heart Failure Reports, 10.1007/s11897-022-00562-1, 19:5, (334-345), Online publication date: 1-Oct-2022. Weber M, O'Malley T, Choi J, Maynes E, Prochno K, Austin M, Wood C, Patel S, Morris R, Massey H and Tchantchaleishvili V (2020) Outcomes of percutaneous temporary biventricular mechanical support: a systematic review, Heart Failure Reviews, 10.1007/s10741-020-09971-7, 27:3, (879-890), Online publication date: 1-May-2022. DeFilippis E, Topkara V, Kirtane A, Takeda K, Naka Y and Garan A (2022) Mechanical Circulatory Support for Right Ventricular Failure, Cardiac Failure Review, 10.15420/cfr.2021.11, 8 Montisci A, Sala S, Maj G, Cattaneo S and Pappalardo F (2022) Comprehensive evaluation of Impella RP ® in right ventricular failure , Future Cardiology, 10.2217/fca-2021-0075, 18:4, (285-298), Online publication date: 1-Apr-2022. Attinger-Toller A, Bossard M, Cioffi G, Tersalvi G, Madanchi M, Bloch A, Kobza R and Cuculi F (2022) Ventricular Unloading Using the ImpellaTM Device in Cardiogenic Shock, Frontiers in Cardiovascular Medicine, 10.3389/fcvm.2022.856870, 9 Albulushi A, Giannopoulos A, Kafkas N, Dragasis S, Pavlides G and Chatzizisis Y (2018) Acute right ventricular myocardial infarction, Expert Review of Cardiovascular Therapy, 10.1080/14779072.2018.1489234, 16:7, (455-464), Online publication date: 3-Jul-2018. Pappalardo F, Scandroglio A and Latib A (2018) Full percutaneous biventricular support with two Impella pumps: the Bi-Pella approach, ESC Heart Failure, 10.1002/ehf2.12274, 5:3, (368-371), Online publication date: 1-Jun-2018. Konstam M, Kiernan M, Bernstein D, Bozkurt B, Jacob M, Kapur N, Kociol R, Lewis E, Mehra M, Pagani F, Raval A and Ward C (2018) Evaluation and Management of Right-Sided Heart Failure: A Scientific Statement From the American Heart Association, Circulation, 137:20, (e578-e622), Online publication date: 15-May-2018.Kuchibhotla S, Esposito M, Breton C, Pedicini R, Mullin A, O'Kelly R, Anderson M, Morris D, Batsides G, Ramzy D, Grise M, Pham D and Kapur N (2017) Acute Biventricular Mechanical Circulatory Support for Cardiogenic Shock, Journal of the American Heart Association, 6:10, Online publication date: 11-Oct-2017. Becher T, Baumann S, Eder F, Fastner C, Behnes M, Loßnitzer D, Dösch C and Borggrefe M (2017) Peripheral Ventricular Assist Devices in Interventional Cardiology: The Impella® Micro-Axial Pump Interventional Cardiology, 10.5772/67883 June 2016Vol 9, Issue 6 Advertisement Article InformationMetrics © 2016 American Heart Association, Inc.https://doi.org/10.1161/CIRCINTERVENTIONS.116.003636PMID: 27188188 Manuscript receivedJanuary 27, 2016Manuscript acceptedApril 5, 2016Originally publishedMay 17, 2016 Keywordsmechanical circulatory supporthemodynamicscirculationinterventioncardiogenic shockPDF download Advertisement SubjectsCardiopulmonary Resuscitation and Emergency Cardiac CareCatheter-Based Coronary and Valvular InterventionsHeart FailureHemodynamics
| Year | Citations | |
|---|---|---|
Page 1
Page 1