PubMed · 1990 · 17 citations · 0 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedic BiomechanicsOrthopedicsShoulder SurgeryJoint InstabilityJoint MechanicsJoint StabilityJoint SurgeryShoulder AnatomyShoulder BiomechanicsGlenohumeral StabilityGlenoid AnatomyLabral AnatomyLabral MechanicsShoulder Stability
In human cadavers we were able to show that the glenohumeral joint is comparable to the model of a physical piston. The labrum glenoidale functions like a valve against atmospheric pressure. It is possible to characterize the behavior of intraarticular negative pressure by the equation (formula; see text). The calculations of the force F of atmospheric pressure tending to resist distraction of the joint surfaces leads to a 95% confidence interval from 6.9 to 22.9 kp. Under a general anesthetic, distraction of the healthy glenohumeral joint also produces negative intraarticular pressure in the area of the fossa glenoidalis in vivo. Joints with a labral tear (Bankart defect) and a chronic instability are not characterized by this phenomenon. A change in intraarticular pressure might stimulate intraarticular pressure receptors. This could be important in functioning as a neuromuscular protection reflex for the joint.