Keratometry for Intraocular Lens Power Calculation Using Orbscan II in Eyes With Laser in situ Keratomileusis

Arthur C.K. Cheng, Dennis S.C. Lam

Journal of Refractive Surgery · 2005 · 26 citations · 17 references

Concepts

Abstract

PURPOSE: To compare the results of comeal keratometry after laser in situ keratomileusis (LASIK) obtained by the Gaussian optics formula and the clinical history method. METHODS: Sixty-one consecutive patients (121 eyes) who had undergone LASIK were recruited in this retrospective case-controlled study. The K-value obtained from the Gaussian optics formula (CalK) based on postoperative corneal topography by Orbscan II (Bausch & Lomb, Rochester, NY) and ultrasound pachymetry was compared with that obtained from the clinical history method (estK). Keratometry measured by these two methods was compared using the paired sample t test and Pearson correlation coefficient. RESULTS: A high correlation was noted between K-value obtained by the clinical history method and the Gaussian optics formula (R = 0.97, P < .001). The mean difference between the two methods is 0.13 diopters (P = .06). CONCLUSIONS: K reading derived from the Gaussian optics formula correlated closely to that obtained from the clinical history method and would be especially useful in patients with no preoperative LASIK treatment data.