International Journal of Clinical Practice · 1999 · 50 citations · 6 references
PharmacyPharmacologyPharmacotherapyClinical PharmacologyPharmaceutical CompliancePrescription DispensingBlood Pressure ControlBlood Pressure ManagementHypertension ControlHypertension ManagementHypertension PharmacotherapyMedication AdherenceAdherence To Antihypertensive TherapyAntihypertensive Drug TherapyAntihypertensive Medication AdherenceAntihypertensive TreatmentBlood PressureCombination TherapyCompliance MonitoringElectronic Medication Monitoring
Compliance with antihypertensive therapy was monitored for three months using an electronic medication dispenser in 35 patients remaining hypertensive despite the once-daily administration of a blood pressure lowering drug (either as monotherapy or as fixed-dose combination therapy). During the monitoring of compliance, the treatment was unchanged but blood pressure decreased significantly (p < 0.001) from 167.9/100.4 +/- 16.3/7.2 mmHg (mean +/- SD) to 152.5/90.9 +/- 20.9/11.5 mmHg. The percentage of days with one opening per day was 80.8 +/- 20.5. Thus, discussing with the patient about compliance with the prescribed drug regimen and monitoring compliance for a few months allows better control of blood pressure. This most likely reflects increased compliance with antihypertensive drug therapy.
6
Blood-pressure control in the hypertensive population
Giuseppe Mancia, Roberto Sega, Camilla Milesi et al. · The Lancet · 1997 · 277 citations
Medicine, Cardiology, Physiology +12
Managing hypertension in general practice: can we do better?
J. Hosie, Ingela Wiklund · PubMed · 1995 · 60 citations