PubMed · 1990 · 15 citations · 0 references
DentistryDental HygieneProsthodonticsImplant ProsthodonticsProsthodontic Laboratory TechniquesRemovable ProsthodonticsImplant Prosthesis Laboratory ProceduresImplant Surface DecontaminationImplant-related Infection PreventionOral HygieneChlorine-based DisinfectantsChlorine-based DisinfectionDental Infection ControlDental Prosthesis HygieneDisinfectionImmersionProsthesis DecontaminationProsthetic Cleaning
The barrier system of specific sequential steps for cleansing and disinfecting dental prosthesis as they enter and leave the laboratory was tested by comparing the use of room-temperature disinfectants for 10 minutes with warmed chlorine-based disinfectants at decreased immersion times. There were no statistically significant differences between 1- or 2-minute disinfection times using warmed 5.25% sodium hypochlorite, Alcide Expore, and Tetravalent Oxident, and using room-temperature Sporicidin for 10 minutes.