Physics in Medicine and Biology · 2016 · 11 citations · 8 references
MedicineBiomedical EngineeringRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningExternal Beam RadiotherapyParticle TherapyProton DosimetryProton TherapyRadiation TherapyRadiobiological ConsiderationsDepth Dose DistributionLateral Dose ProfilesModulator DesignPercentage Depth DoseProton Therapy Dosimetry
A new method for the design of stepless beam modulators for proton therapy is described and verified. Simulations of the classic designs are compared against the stepless method for various modulation widths which are clinically applicable in proton eye therapy. Three modulator wheels were printed using a Stratasys Objet30 3D printer. The resulting depth dose distributions showed improved uniformity over the classic stepped designs. Simulated results imply a possible improvement in distal penumbra width; however, more accurate measurements are needed to fully verify this effect. Lastly, simulations were done to model bio-equivalence to Co-60 cell kill. A wheel was successfully designed to flatten this metric.
8