Determining the optimum gateway location for extremely close coal seams

XU Meng-tang

Journal of China University of Mining and Technology · 2012 · 19 citations · 0 references

Concepts

Abstract

Calculations were done to estimate the strain and stress distributions in the floor under a coal pillar left in an upper coal seam in close conjunction with an underlying seam.The Caocun coal mine number 10 and 11 seams were used as a basis for the model.The calculations predict that the maximum strain in the floor caused by the bearing pressure from the number 10 seam being mined is 26.1 m.This is 2.8 times the distance between seams.The stress distributions in the floor around the pillar are significantly non-uniform.The variation rate coefficient in the stress fields was defined to evaluate this non-uniformity.A inner stagger distance for the gateway of the 209 work face in the number 11 seam was determined: a value of 7.5 m is reasonable for a 1.5 safety factor and an assumed uniform loading.Field studies show this stagger layout to be suitable and that the support from the gateway is improved and that strong pressures do not appear after mining.