Higher-order sine fitting algorithm for dielectric loss measurement

Wang Weile

2001 · 13 citations · 0 references

Concepts

Abstract

In the digital measurement of dielectric loss angle, the non synchronisation between the data sampling rate and the frequency of the power network as well as the network's various harmonic components can cause remarkable error. The accuracy can be improved with a new method, the higher order sine fitting algorithm. The method takes the power frequency as an unknown parameter and uses a nonlinear least squares fitting procedure based on a higher order model to process the sampling data. The discrete Fourier transform (DFT) method is also used to calculate the initial value and speed for the iterative computation. Studies show that the maximum measurement error is limited to 0.0003 even in noisy conditions, and it takes less than 20ms for one calculation. Therefore, the algorithm can be used for on line measurements of dielectric loss angle.