Proceedings of the CSEE · 2006 · 12 citations · 0 references
EngineeringComputer ScienceElectrical EngineeringMachine LearningPower ElectronicsTime Series AnalysisActive FiltersDigital Signal ProcessingElectrical MeasurementHarmonic AnalysisNeural NetworksPower QualityActive Harmonic FilteringActive Power FilterNeural Network ModelingPrecisionTraining Sample Selection
Magnitude and phase angle of harmonics are two key measuring parameters in active power filter , both of them can be non-linearly mapped by ANN. A method is proposed to simultaneously measure the two parameters. A three layers feed forward neural network whose hidden layer adopts tangent function and the output layer adopts linear function is constructed to simulate the method. The training method and training sample composition in the neural network are presented using 3rd harmonic as an example. Training the neutral network with training samples first, then measuring untrained samples, the simulation is performed by using Matlab’s toolbox and the results show the validity of the proposed harmonic measuring approach. Comparison with traditional FFT harmonic measuring method shows that the proposed method has higher precision and flexibility in real time harmonic measuring and the proposed method has no restrict limitation to the samples number. The off-line trained MLFNN may suit for the occasion where the harmonic source is constant.