Determination of the thermal influence zone of buried hot oil pipeline on steady operation

Unknown author(s)

Journal of the University of Petroleum,China · 2004 · 30 citations · 0 references

Concepts

Abstract

A mathematical model for determining the thermal influence zone of buried hot oil pipeline was developed and solved numerically by the finite element method. Based on the model,the effect of soil temperature surrounding pipeline,oil temperature,pipe diameter, buried depth of pipe and heat conductivity coefficient of soil on the thermal influence distance in the horizontal direction of pipeline was analyzed quantitatively. The horizontal thermal influence distances of buried pipelines with the diameters of 426 mm and 720 mm at 22℃,15 ℃ and 8℃were determined respectively. Compared with other factors,the pipe buried depth variation in the commonly adopted range from 1.2 to 1.8 meters leads to little difference in the horizontal thermal influence distance. The calculated results agree well with the field-measured data. The rationality of the model was verified.