Plasma renin concentration: comparison of angiotensinase inhibitors and correlation with plasma renin activity and aldosterone.

Martin E. Kodish, Fred H. Katz

PubMed · 1974 · 31 citations · 16 references

Concepts

Abstract

Abstract There are wide variations between laboratories in the results obtained for the estimation of the renin content of plasma. Much of this is due to the many different methods employed for inhibiting angiotensinases. In comparing those different methods in the context of a plasma renin concentration assay, phenylmethylsulfonylfluoride was found to be superior to dimercaprol, 8-hydroxyquinoline, and acidification in preserving angiotensin I. In the presence of adequate angiotensinase inhibition there was an excellent correlation between plasma renin activity and plasma renin concentration determined in plasma from 30 male hypertensive patients with low or normal levels of renin. The plasma renin concentration assay method can also be used for samples with high levels of renin. Plasma renin concentration and plasma renin activity correlated equally well with plasma aldosterone. This suggests that in routine clinical screening the plasma renin activity assay gives adequate information and the more complex plasma renin concentration assay need not be done unless aberrations in renin substrate, which could be responsible for dissociation of renin concentration from renin activity, are suspected.

References

16