Radiology · 2016 · 64 citations · 22 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyImage InterpretationBreast AssessmentBreast CalcificationsBreast Density AssessmentBreast ImagingBreast Lesion CharacterizationBreast TomosynthesisAssessmentsBi-rads ClassificationBreast Lesion DiagnosisInformed ConsentInstitutional Review Board ApprovalMammographyPositive Predictive ValueTomosynthesis Assessment Of Calcifications
Purpose To evaluate the effect of tomosynthesis in diagnostic mammography on the Breast Imaging Reporting and Data System (BI-RADS) final assessment categories over time. Materials and Methods This retrospective study was approved by the institutional review board. The authors reviewed all diagnostic mammograms obtained during a 12-month interval before (two-dimensional [2D] mammography [June 2, 2010, to June 1, 2011]) and for 3 consecutive years after (tomosynthesis year 1 [2012], tomosynthesis year 2 [2013], and tomosynthesis year 3 [2014]) the implementation of tomosynthesis. The requirement to obtain informed consent was waived. The rates of BI-RADS final assessment categories 1-5 were compared between the 2D and tomosynthesis groups. The positive predictive values after biopsy (PPV3) for BI-RADS category 4 and 5 cases were compared. The mammographic features (masses, architectural distortions, calcifications, focal asymmetries) of lesions categorized as probably benign (BI-RADS category 3) and those for which biopsy was recommended (BI-RADS category 4 or 5) were reviewed. The χ(2) test was used to compare the rates of BI-RADS final assessment categories 1-5 between the two groups, and multivariate logistic regression analysis was performed to compare all diagnostic studies categorized as BI-RADS 3-5. Results There was an increase in the percentage of cases reported as negative or benign (BI-RADS category 1 or 2) with tomosynthesis (58.7% with 2D mammography vs 75.8% with tomosynthesis at year 3, P < .0001). A reduction in the percentage of probably benign (BI-RADS category 3) final assessments also occurred (33.3% with 2D mammography vs 16.4% with tomosynthesis at year 3, P < .0001). Although the rates of BI-RADS 4 or 5 assessments did not change significantly with tomosynthesis (8.0% with 2D mammography vs 7.8% with tomosynthesis at year 3, P = .2), there was a significant increase in the PPV3 (29.6% vs 50%, respectively; P < .0001). These trends increased during the 3 years of tomosynthesis use. Conclusion Tomosynthesis in the diagnostic setting resulted in progressive shifts in the BI-RADS final assessment categories over time, with a significant increase in the proportion of studies classified as normal, a continued decrease in the rate of studies categorized as probably benign, and improved diagnostic confidence in biopsy recommendations. (©) RSNA, 2016.
22
Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
Sarah M. Friedewald, Elizabeth A. Rafferty, Stephen L. Rose et al. · JAMA · 2014 · 838 citations