Publication | Open Access
The Impact of Entry Technique and Access Diameter on Prelabour Rupture of Membranes Following Primary Fetoscopic Laser Treatment for Twin-Twin Transfusion Syndrome
41
Citations
27
References
2016
Year
Instrument choice at fetoscopic laser procedures did not affect outcomes <4 weeks. Access diameter may affect the likelihood for PTB <28 weeks. Cervical length is critically associated with obstetrical outcomes following laser surgery.