An evaluation and comparison with rigid sigmoidoscopy

Theodore W. Bohlman, Ronald M. Katon, Gilbert R. Lipshutz, Michael F. Mccool, Frederick W. Smith

1977 · 11 citations · 7 references

Concepts

Abstract

A flexible 60-cm fiberoptic sigmoidoscope was evaluated in 139 patients'. In 120 patients flexible sigmoidoscopy was compared with routine rigid sigmoidoscopy with respect to patient tolerance, distance of inspection, procedure time, and diagnostic yield. All patients were prepared with a single cleansing enema, and given no analgesia. Despite the fact that the flexible instrum~nt was inserted nearly 3 times as far into the colon (55 cm versus 20 cm), more patients preferred the flexible examination. Significant pathological lesions were discovered by the flexible examination in 39% of patients, whereas rigid sigmoidoscopy discovered lesions in only 13%. Fluoroscopy performed during flexible sigmoidoscopy in 19 additional patients revealed that the instrument tip had reached the descending colon or beyond in 84% of patients. There were no complica­ tions. The flexible fiberoptic pansigmoidoscope offers promise as a practical diagnostic tool for a rapid and complete examination in patients with suspected colorectal diseases. The standard 25-cm rigid sigmoidoscope has been used in the evaluation of colorectal disease for decades. 1 In spite of its unquestioned value in the evaluation of patients with colonic problems, serious limitations in its diagnostic usefulness remain. The major deficiency of this instrument is that the average sigmoidoscopist inspects primarily the distal 15 to 18 cm of colon. 2 Diverticular disease, strictures, local­ ized inflammatory bowel disease, polyps, and colon can­ cer often occur more proximally in the colon, just beyond the reach ofthe rigid instrument. Previous studies indi­ cated that perhaps 70% of colon neoplasms were located in the distal 25 cm of bowel and should be seen by this instrument. 3 Recent data, however, suggest a major change in distribution, with a greater number oflesions above the level of the rectosigmoid.4, 5-10 Thus, the po­ tential of finding colon cancer by rigid sigmoidoscopy alone may be diminishing. Additional problems with rigid sigmoidoscopy include unavoidable discomfort and difficulties in traversing the redundant lower sigmoid segment. These problems may lead the sigmoidoscopist to abandon the procedure before a thorough examination is accomplished. There is a need for an instrument which would allow an expedient and more extensive examination ofthe lower colon with less patient discomfort. Newer flexible fiberoptic instruments have this potential. Salmon and his group were the first to report their experience with such an instrument. 7

References

7