NATURAL FIRES IN LARGE SCALE COMPARTMENTS

B.R. Kirby, D. E. Wainman, L. N. Tomlinson, T Kay, B. N. Peacock

1999 · 51 citations · 3 references

Concepts

Abstract

British Steel plc, Swinden Technology Centre has recently carried out a programme of tests with the UK Fire Research Station in order to simulate the behaviour of natural fires in large scale compartments. By studying a range of fire severity conditions, it was found that one of the more recently developed relationships for calculating time equivalent presented in the September 1992 draft of Eurocode 1: Actions on Structures Exposed to Fire, can provide safe realistic predictions. However, in a later draft of ECI the factors used for describing the thermal properties of the compartment, were amended resulting in unsafe solutions. It is advocated they revert back to those given in the September 1992 draft. From the various temperature measurements made of the atmosphere and indicative steel sections included in the tests, other aspects of the Eurocodes on Fire Actions were investigated. In particular, these included the proposed relationships for calculating heat transfer to protected steel members (EC3) and parametric time temperature curves for the combustion gases.

References

3