Quantifying the Amount of Bleeding and Associated Changes in Intra-Abdominal Pressure and Mean Airway Pressure in Patients Undergoing Lumbar Fixation Surgeries: A Comparison of Three Positioning Systems

19

Citations

12

References

2016

Year

Abstract

Positioning on a spine table results in less blood loss and low mean airway pressure. The Wilson's frame results in high IAP, increased mean airway pressure, and more blood loss. The thermomodulated frame increases mean airway pressure and produces a moderate increase in IAP and airway pressure.