Circulation Arrhythmia and Electrophysiology · 2016 · 82 citations · 26 references
MedicineCardiologySurgeryCardiothoracic RadiologyCardiothoracic SurgeryInterventional CardiologyAblation TherapyCardiac ArrhythmiasCatheter AblationVentricular TachycardiaAblation Site LocalizationCatheter Ablation MappingIntracardiac EchocardiographyIntracardiac MappingPapillary MusclesSurgical AblationVentricular Tachycardia Ablation
BACKGROUND: Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. METHODS AND RESULTS: Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). CONCLUSIONS: Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias.
26
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Etienne Aliot, William G. Stevenson, Jesús Almendral-Garrote et al. · Heart Rhythm · 2009 · 771 citations
Hiroshi Nakagawa, William S. Yamanashi, Jan Piťha et al. · Circulation · 1995 · 624 citations
Medicine, Surgery, Heat Transfer +14
Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter Ablation
Paul Khairy, Patrick Chauvet, John W. Lehmann et al. · Circulation · 2003 · 515 citations
Medicine, Cardiology, Anesthesia +13
Etienne Aliot, William G. Stevenson, Jesús Almendral-Garrote et al. · EP Europace · 2009 · 418 citations · Full text