CASE STUDIES OF PASSIVE TREATMENT SYSTEMS: VERTICAL FLOW SYSTEMS

Arthur Rose, Jonathan M. Dietz

Journal American Society of Mining and Reclamation · 2002 · 31 citations · 7 references

Concepts

Abstract

studies of 30 vertical flow systems (VFS or SAPS) have been compiled. Data includes inflow and outflow chemistry, flow rates, dimensions, design features and problems encountered. The increase in net alkalinity ranges widely, from 7 to 686 mg/L CaCO3 (median 160 mg/L), but is positive for all systems. Systems having low influent acidity added little net alkalinity compared to units with high influent acidity. Increased retention time shows a correlation with increase in net alkalinity, suggesting that a standard retention time is not necessarily optimum. A regression of influent acidity loading vs. effluent alkalinity indicates that an acidity loading less than 40 g/m 2 /d, on average, produces net alkaline effluent (r 2 =0.55, p=0.0002). Similarly, 12 of the VFS had net acid effluent and are interpreted to be at the limit of VFS effectiveness. Most of the 12 units decrease acidity by between 25 and 50 g/m 2 /d. These values are similar to the 25 g/m 2 /d determined by Dietz and Stidinger (1996). A value of 25 g/m 2 /d is suggested as a design criterion for VFS, in place of retention time. Results for several units suggest that this loading may be increased by addition of fine limestone to the

References

7