Diabetes Care · 2016 · 118 citations · 19 references
MedicineClinical PharmacyEndocrinologyDiabetologyMetabolic RegulationTelehealth InformaticsBlood Glucose MonitoringDiabetes ControlDiabetes ManagementDiabetes MellitusGlycemic ControlGlycemic MonitoringArtificial Pancreas MonitoringArtificial Pancreas SystemsGlucose ConcentrationGlucose MonitoringGlucose Monitoring DevicesGlucose SensingGlucose SensorsType 1 Diabetes Monitoring
The study assessed whether the portable, wearable, wireless artificial pancreas system (DiAs) could improve overnight‑only and 24/7 closed‑loop glucose control in patients with type 1 diabetes. Thirty adults with type 1 diabetes across six centers in four countries underwent a 2‑week baseline sensor‑augmented pump period followed by 2 weeks of overnight‑only closed‑loop control and 2 weeks of 24/7 closed‑loop control at home, with glucose metrics compared to baseline. Closed‑loop control reduced hypoglycemia, increased time in target range, and lowered glucose variability compared to baseline, with 24/7 control providing additional daytime hypoglycemia protection and overall demonstrating safety and effectiveness.
OBJECTIVE To evaluate the efficacy of a portable, wearable, wireless artificial pancreas system (the Diabetes Assistant [DiAs] running the Unified Safety System) on glucose control at home in overnight-only and 24/7 closed-loop control (CLC) modes in patients with type 1 diabetes. RESEARCH DESIGN AND METHODS At six clinical centers in four countries, 30 participants 18–66 years old with type 1 diabetes (43% female, 96% non-Hispanic white, median type 1 diabetes duration 19 years, median A1C 7.3%) completed the study. The protocol included a 2-week baseline sensor-augmented pump (SAP) period followed by 2 weeks of overnight-only CLC and 2 weeks of 24/7 CLC at home. Glucose control during CLC was compared with the baseline SAP. RESULTS Glycemic control parameters for overnight-only CLC were improved during the nighttime period compared with baseline for hypoglycemia (time <70 mg/dL, primary end point median 1.1% vs. 3.0%; P < 0.001), time in target (70–180 mg/dL: 75% vs. 61%; P < 0.001), and glucose variability (coefficient of variation: 30% vs. 36%; P < 0.001). Similar improvements for day/night combined were observed with 24/7 CLC compared with baseline: 1.7% vs. 4.1%, P < 0.001; 73% vs. 65%, P < 0.001; and 34% vs. 38%, P < 0.001, respectively. CONCLUSIONS CLC running on a smartphone (DiAs) in the home environment was safe and effective. Overnight-only CLC reduced hypoglycemia and increased time in range overnight and increased time in range during the day; 24/7 CLC reduced hypoglycemia and increased time in range both overnight and during the day. Compared with overnight-only CLC, 24/7 CLC provided additional hypoglycemia protection during the day.
19
Home Use of an Artificial Beta Cell in Type 1 Diabetes
Hood Thabit, Martin Tauschmann, Janet M. Allen et al. · New England Journal of Medicine · 2015 · 448 citations · Full text
Ahmad Haidar, Laurent Legault, Virginie Messier et al. · The Lancet Diabetes & Endocrinology · 2014 · 213 citations
Medicine, Endocrinology, Diabetology +10