AIP conference proceedings · 2016 · 10 citations · 4 references
EngineeringElectrical EngineeringElectrochemical EngineeringElectrochemistryEnergy SystemsBattery SystemsBattery TechnologyBattery TestingElectrochemical CellsEnergy StorageGalvanic CellsBattery CharacterizationBattery ModelingBattery SimulationEquivalent Circuit AnalysisEquivalent Circuit ModelingInternal ResistanceLithium-ion BatteriesParallel Rc Circuits
In this research, a lithium battery model, as a component in a simulation environment, was developed and implemented using Scicos/Xcos graphical language programming. Scicos used in this research was actually Xcos that is a variant of Scicos which is embedded in Scilab. The equivalent circuit model used in modeling the battery was Double Polarization (DP) model. DP model consists of one open circuit voltage (VOC), one internal resistance (Ri), and two parallel RC circuits. The parameters of the battery were extracted using Hybrid Power Pulse Characterization (HPPC) testing. In this experiment, the Double Polarization (DP) electrical circuit model was used to describe the lithium battery dynamic behavior. The results of simulation of the model were validated with the experimental results. Using simple error analysis, it was found out that the biggest error was 0.275 Volt. It was occurred mostly at the low end of the state of charge (SOC).