Successful re-intervention with metal stent trimming using argon plasma coagulation after endoscopic ultrasound-guided hepaticogastrostomy

Kei Yane, Akio Katanuma, Hiroyuki Maguchi, Kuniyuki Takahashi, Manabu Osanai, Toshifumi Kin, Satoshi Ikarashi, Ryuki Minami, Manabu Sen-yo, Itsuki Sano,

Endoscopy · 2014 · 14 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Recently, endoscopic ultrasound (EUS)-guided biliary drainage has been introduced as an alternative method after failed endoscopic biliary drainage, particularly in patients with a pre-existing duodenal obstruction [1] [2] [3]. A longer self-expandable metal stent (SEMS) is usually used for EUS-guided hepaticogastrostomy (EUS-HGS) to prevent stent migration. However, re-intervention after EUS-HGS is challenging because of the protrusion of the SEMS into the stomach. Metal stent trimming using argon plasma coagulation (APC) has been reported to be a useful option for stent-related complications such as dislocation [4] [5]. We report a case in which successful re-intervention after EUS-HGS was made possible by metal stent trimming using APC.