Nature of energy losses in air capacitors at low frequencies

A. V. Astin

Journal of research of the National Bureau of Standards · 1939 · 24 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

The power factors of a number of types of air capacitors have been observed in the frequency range from 60 to 1,000 cis. The method of measurement permitted evaluation of true, or "absolute," power-factor values as small as 5X10-7 In guard-ring air capacitors the losses occur on the surfaces of the electrodes and give rise to a power factor which is proportional to capacitance (inverse electrode separation). The same type of losses in addition to the losses in the solid insulation, are evident in two-electrode capacitors.