Mass Transfer Coefficients for CO<sub>2</sub> Absorption into Aqueous Ammonia Solution Using a Packed Column

Qing Zeng, Yincheng Guo, Zhenqi Niu, Wenyi Lin

Industrial & Engineering Chemistry Research · 2011 · 91 citations · 35 references

Concepts

Abstract

The absorption of carbon dioxide into aqueous ammonia solution using a packed column was investigated. The volumetric overall mass transfer coefficients ( K G a V ) for CO 2 absorption into aqueous ammonia solutions were evaluated over ranges of main operating variables, that is, up to 15 kPa partial pressure of CO 2, 61–214 m 3 /(m 2 ·h) gas flow rate, 0.76–3.06 m 3 /(m 2 ·h) liquid flow rate, 2%∼16% ammonia mass fraction, and 20–50 °C temperature. An empirical K G a V correlation for this system was proposed. Experimental results show that the mass transfer process in CO 2 absorption into aqueous ammonia solution is mainly controlled by the resistance in the liquid phase and the ammonia concentration has a great effect on the overall mass transfer coefficient.