2002 · 11 citations · 3 references
EngineeringCivil EngineeringFinite Element AnalysisStructural AnalysisStructural EngineeringConnection DesignPlate AnalysisStructural ConnectionsStructural DesignStructural Finite Element AnalysisStructural MechanicsConnectorsGirder DesignShear BehaviorShear Connection DesignShear ConnectionsShear Connector Behavior
This paper presents slip behavior of perfobond rib shear connectors on push-out and girder bending tests and their treatment in FEM analysis using plates and combination elements. The number of holes and thickness of ribs are varied in twelve push-out test specimens. The combination elements in FEM between concrete and the perfobond ribs are modeled by spring constants to express the applied load-slip relations.