Investigative Radiology · 2003 · 81 citations · 18 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyMagnetic Resonance ImagingMedical ImagingPerfusion ImagingPulmonary ImagingGradient Echo SequencesLung Perfusion ImagingLung Perfusion ScansMagnetic Resonance Imaging PerfusionPerfusion Imaging SequencesSignal-to-noise RatioSignal-to-noise Ratio AnalysisThree-dimensional Medical Imaging
RATIONALE: Contrast-enhanced magnetic resonance imaging (MRI) of lung perfusion requires a high spatial and temporal resolution. Partially parallel MRI offers an improved spatial and temporal resolution. OBJECTIVE: To assess the feasibility of partially parallel MRI for the assessment of lung perfusion. METHODS: Two healthy volunteers and 14 patients were examined with a contrast-enhanced 3D gradient-echo pulse sequence with partially parallel image acquisitions (TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; voxel size 3.6 x 2.0 x 5.0 mm3, TA: 1.5 seconds). The image analysis included an analysis of the signal-to-noise ratio in the lungs in areas with normal and impaired perfusion. 3D MR perfusion image data were analyzed for perfusion defects and compared with radionuclide perfusion scans, which were available for 10 of 14 patients. RESULTS: The analysis of the 3D perfusion-weighted data allowed a clear differentiation of perfusion abnormalities: MRI showed normal lung perfusion in 9 of 16 cases, whereas perfusion abnormalities were observed in 7 cases. When compared with the radionuclide perfusion scans, a good intermodality agreement was shown (kappa = 0.74). When compared with normally perfused lung a significantly lower signal to noise ratio was observed in hypoperfused lung (7 versus 17; P = 0.02). CONCLUSION: Partially parallel MRI might be used for the assessment of lung perfusion. Future studies are required to further evaluate the diagnostic impact of this technique.
18
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text
The rician distribution of noisy mri data
Hákon Guðbjartsson, Samuel Patz · Magnetic Resonance in Medicine · 1995 · 2.5K citations
Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
Hans Svanholm, H Starklint, H.J.G. Gundersen et al. · Apmis · 1989 · 455 citations