TDLAS-based Measurements of Temperature, Pressure, and Velocity in the Isolator of an Axisymmetric Scramjet

Michael Brown, Dominic Barone, Todd Barhorst, Dean Eklund, Mark Gruber, Tarun Mathur, Ryan Milligan

2010 · 25 citations · 12 references

Concepts

Abstract

Using tunable diode laser absorption spectroscopy (TDLAS), water-based measurements of path-integrated static temperature, static pressure, and local velocity are made in the isolator of a direct-connect, ethylene-fueled, axisymmetric scramjet engine. Three optical lines of sight are directed across the midplane of the isolator just downstream of the facility nozzle. For the data set presented here, the scramjet engine was operated to simulate relatively low flight Mach number conditions of M ~ 3. The flight conditions were achieved using a dry, heated, but non-vitiated inflow which provided a challenging environment for the water-based direct-absorption TDLAS implementation. The TDLAS-derived temperature and velocity agree well with facility operating conditions while the derived pressure measurements highlight the need for improved pressure-broadening data. With a pressure-correction factor, the TDLAS-derived values for mass flux agree well with the measured facility mass flow. The measurements are discussed in the context of a 1-D analytical model and 3-D CFD calculations. Notably, the dynamic behavior of the velocity measurements under conditions of low isolator margin are consistent with the presence of a local shock structure predicted by the CFD computations.

References

12