Signal & Image Processing An International Journal · 2015 · 12 citations · 21 references
ComputingBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyHepatobiliary ImagingImage SegmentationMedical Image AnalysisMedical ImagingVolume SegmentationComputer TomographyOrgan SegmentationRegularizationRegularization TechniquesTomographic Image SegmentationTomography
Segmentation of organs from medical images is an active and interesting area of research. Liver segmentation incurs more challenges and difficulties compared with segmentation of other organs. In this paper we demonstrate a liver segmentation method for computer tomography images. We revisit the distance regularization level set (DRLS) model by deploying new balloon forces. These forces control the direction of the evolution and slow down the evolution process in regions that are associated with weak or without edges. The newly added balloon forces discourage the evolving contour from exceeding the liver boundary or leaking at a region that is associated with a weak edge, or does not have an edge. Our experimental results confirm that the method yields a satisfactory overall segmentation outcome. Comparing with the original DRLS model, our model is proven to be more effective in handling oversegmentation problems.
21
Vicent Caselles, Ron Kimmel, Guillermo Sapiro · 2002 · 1.2K citations
Active shape model segmentation with optimal features