Binaural hearing aid communication shown to improve sound quality and localization

Ravi Sockalingam, Marcus Holmberg, Karin Eneroth, Michael Shulte

The Hearing Journal · 2009 · 33 citations · 1 references

Concepts

Abstract

In the world of amplification where there is a deluge of information about new technologies, selecting hearing instruments based on evidence of effectiveness and benefit to the user is no longer just an option; it is a mandatory part of the rehabilitation process. Hearing care practitioners bear responsibility for discerning and differentiating science from marketing in their effort to apply evidence-based principles in clinical decisions. Hearing instrument manufacturers also have a responsibility to provide laboratory as well as real-world data regarding the benefit of features they develop. One emerging technology that has generated great interest among clinicians and clients alike is binaural wireless communication between hearing aids in the right and left ears. Binaural wireless technology can be viewed at three different levels. At the most basic level, the volume controls between the right and left instruments are simply matched. This technology has been around for several years. At the next level up, signal processing features such as noise reduction and directionality are synchronized between the two sides, contributing to a balanced sound experience for the wearer. This binaural capability is offered by a couple of manufacturers. At the highest level, the compression settings on the right and left instruments are optimized with an aim of improving spatial fidelity and resolution. This technology is offered in addition to the synchronization of noise reduction and directionality. Different gain settings are used in an attempt to preserve as much as possible the level difference between ears so that the wearer's localization ability on the horizontal plane is not unduly compromised. While real-world evidence of the effectiveness of this technology has recently been demonstrated,1,2 the effectiveness of binaural communication at all three levels has not been systematically investigated in the controlled laboratory or simulated environment. To this end, our report endeavors to provide laboratory-based clinical evidence of the effectiveness of binaural wireless communication with respect to sound localization and perceived sound quality in noisy backgrounds. METHOD The study sample comprised 30 participants (22 males and 8 females) between 41 and 81 years of age, with a mean of 66 years. Fourteen of them were new users of amplification and the remaining 16 were experienced users. All had mild to moderate sensorineural hearing loss. All the subjects were fitted with binaural wireless (Oticon Dual XW) hearing aids; they were provided with open or plus domes, as prescribed by the fitting software. The binaural wireless instruments were evaluated in two conditions: binaural communication turned on (Binaural ON), and binaural communication turned off (Binaural OFF). In a cross-over study design, 15 participants commenced the study in the Binaural ON condition while the remaining 15 began in the Binaural OFF condition. Participants were given the opportunity to acclimatize to the instruments in the real world for 2 weeks in each condition prior to undergoing controlled laboratory-based performance measurements at the Hörzentrum, Oldenburg, Germany. For these laboratory measurements the Binaural ON and OFF conditions were set up as two separate programs in Dual, and selection of the appropriate program was made by the investigator via the streamer. Participants had no knowledge during the entire study whether their instruments were in the Binaural ON or Binaural OFF condition. We conducted localization tests in the laboratory using the set up illustrated in Figure 1. Eight loudspeakers were placed 15 degrees apart from 0º to 105º azimuth in a sound-treated room. The target signal was a 60-dB SPL bird chirp that was presented three times randomly from each of the eight speakers. The target and noise signals were presented from 0º to −105º (left) and 0º to +105º (right) azimuth by keeping the eight speakers in the same position, but re-orienting the participants by 105º. The noise signal was unmodulated speech-shaped noise that was presented at a constant level of 55 dB SPL at +105º (right) or −105º (left) azimuth.Figure 1: Localization set up using an eight-speaker arrangement whereby target signal is presented from 0º to −105º (left) and 0º to +105º (right) azimuths. Noise is fixed at 55 dB SPL at 105º azimuth.The speakers were numbered so participants could identify the speaker from which the target signal was emanating. The localization errors from 0º to −105º (left) and 0º to +105º (right) azimuth were summed and then compared between the Binaural ON and Binaural OFF conditions. Sound quality evaluations were performed in the Communication Acoustic Simulator at the Hörzentrum. To investigate the naturalness of sound in three listening environments we had both groups of participants answer a questionnaire in both the Binaural ON and Binaural OFF conditions. As a key dimension of sound quality, naturalness of sound ranked fifth among ten factors that correlated most strongly with user satisfaction in a survey of 3000 hearing instrument users.1 The scale used to evaluate naturalness in this study comprised six ratings ranging from 1 to 6, with 1 meaning the sound was “very unnatural” and 6 meaning it was “very natural.” The three simulated communication environments used in the study were café, garden, and street. RESULTS The results of the localization test and sound quality ratings are shown in Figures 2 and 3, respectively.Figure 2: Mean (±1 SD) localization errors (in degree) in noise in Binaural ON and Binaural OFF conditions from 0º to −105º and 0º to +105º. There were significantly more localization errors in the Binaural OFF condition (p<0.05).Figure 3: Mean (±1 SD) ratings of naturalness of sound on a six-point scale in the Communication Acoustic Simulator. Dual XW was rated significantly more natural (p<0.05) in the Binaural ON condition than in the Binaural OFF condition in the café environment.When binaural communication was turned on (the Binaural ON condition), participants made significantly fewer localization errors in noise (p<0.05) than when the binaural communication was turned off (Binaural OFF condition). The average localization performance in the Binaural ON condition was 14% better than performance in the Binaural OFF condition. With regard to sound quality, the naturalness of sound was rated significantly better in the Binaural ON condition than in the Binaural OFF condition in the café environment. In the street environment, although the average rating for naturalness was better in the Binaural ON condition than in the Binaural OFF condition, the improvement was not statistically significant. No difference in naturalness of sound was noted between the two conditions in the park environment. This latter finding could be expected in a relatively unchallenging listening environment such as a park. CONCLUSION The purpose of this study was to systematically demonstrate the effectiveness of binaural communication between instruments in terms of sound localization and sound quality in noise. People with hearing loss know all too well that communicating in a noisy café or restaurant can be very challenging. In such environments, having binaural communication turned on could allow the hearing aid wearer to experience a more natural sound quality and help locate the target speaker better against a background of competing speakers. In summary, the present study demonstrated that, by having noise reduction and directionality synchronized and compression settings optimized between ears, better localization ability and naturalness of sound in difficult listening situations could be achieved. However, in making clinical decisions hearing care practitioners must consider this laboratory evidence in conjunction with real-world evidence.

References

1