Energies · 2016 · 58 citations · 26 references
EngineeringElectrical EngineeringMaterials ScienceBuilding MaterialsMaintenance EngineeringMechanical Behavior Of MaterialsDielectric MaterialsInsulation MaterialsInsulation SystemsComposite InsulationComposite Insulation MaterialsCondition Monitoring Of InsulationInsulation AgingInsulation Degradation AssessmentInsulation DurabilityInsulation Materials CharacterizationTransformer Insulation
Interest has risen among utilities in using natural ester (NE) insulating oils in transformers as a substitute for conventional mineral oil. However, present understanding on aging behaviour of NE-paper composite insulation system and knowledge on application of existing condition monitoring tools for NE-based insulation are inadequate. This limits the cost effective and reliable field applications of NE insulating oil. To pave the way the application of NE-based insulation in transformers, a systematic study has been performed to compare the aging behaviour of transformer grade pressboard (PB) impregnated in NE and conventional mineral oil. Applicability of a number of chemical and physical parameters, including acidity value, dielectric dissipation factor (DDF), viscosity, and colour for assessing the quality of NE insulating oil is also discussed in this paper. Comparisons are made based on the limiting values provided in the related IEEE Standard and properties of mineral oil under similar aging conditions.
26
Aging of Oil-Impregnated Paper in Power Transformers
L.E. Lundgaard, W. C. Hansen, D. Linhjell et al. · IEEE Transactions on Power Delivery · 2004 · 695 citations
Mineral insulating oil in transformers
T.O. Rouse · IEEE Electrical Insulation Magazine · 1998 · 381 citations
Moisture equilibrium in transformer paper-oil systems
Yanqing Du, Markus Zahn, Bernard C. Lesieutre et al. · IEEE Electrical Insulation Magazine · 1999 · 371 citations · Full text