Technology in Cancer Research & Treatment · 2013 · 39 citations · 15 references
MedicineOncologyRadiation OncologyRadiation DosimetryRadiation SafetyTreatment PlanningDose CalibrationPatient Radiation SafetyQuality Assurance In DosimetryRadiation Imaging SystemsRadiation TherapyAccuracyPatient Positioning AccuracyPatient Positioning DevicesPatient Positioning SystemsPatient Positioning VerificationRadiotherapy Quality AssuranceTreatment Quality AssuranceTreatment Setup Verification
In an increasing number of clinical indications, radiotherapy with accelerated particles shows relevant advantages when compared with high energy X-ray irradiation. However, due to the finite range of ions, particle therapy can be severely compromised by setup errors and geometric uncertainties. The purpose of this work is to describe the commissioning and the design of the quality assurance procedures for patient positioning and setup verification systems at the Italian National Center for Oncological Hadrontherapy (CNAO). The accuracy of systems installed in CNAO and devoted to patient positioning and setup verification have been assessed using a laser tracking device. The accuracy in calibration and image based setup verification relying on in room X-ray imaging system was also quantified. Quality assurance tests to check the integration among all patient setup systems were designed, and records of daily QA tests since the start of clinical operation (2011) are presented. The overall accuracy of the patient positioning system and the patient verification system motion was proved to be below 0.5 mm under all the examined conditions, with median values below the 0.3 mm threshold. Image based registration in phantom studies exhibited sub-millimetric accuracy in setup verification at both cranial and extra-cranial sites. The calibration residuals of the OTS were found consistent with the expectations, with peak values below 0.3 mm. Quality assurance tests, daily performed before clinical operation, confirm adequate integration and sub-millimetric setup accuracy. Robotic patient positioning was successfully integrated with optical tracking and stereoscopic X-ray verification for patient setup in particle therapy. Sub-millimetric setup accuracy was achieved and consistently verified in daily clinical operation.
15
Clinical Results of Carbon Ion Radiotherapy at NIRS
Hirohiko Tsujii, Jun‐etsu Mizoe, Tadashi Kamada et al. · Journal of Radiation Research · 2007 · 211 citations · Full text
Proton Beams to Replace Photon Beams in Radical Dose Treatments
Herman D. Suit, S. Nahum Goldberg, Andrzej Niemierko et al. · Acta Oncologica · 2003 · 145 citations · Full text