Concepedia

Publication | Closed Access

Hydrodynamic Tweezers: Impact of Design Geometry on Flow and Microparticle Trapping

84

Citations

32

References

2012

Year

Abstract

Here we explore the role of microfabricated device geometry on frequency-dependent low Reynolds number steady streaming flow and particle trapping behavior. In our system, flow and particle trapping is induced near an obstruction or cavity located in an otherwise rectilinear oscillating flow of frequency ω and amplitude s in a fluid of kinematic viscosity ν. This work expands prior studies to characterize nine distinct obstruction/cavity geometries. The imaged microeddy flows show that the device geometry affects the eddy number, shape, structure, and strength. Comparison of measured particle trap locations with the computed eddy flow structure shows that particles trap closer to the wall than the eddy core. Trapping strength and location are controlled by the geometry and the oscillation frequency. In most cases, the trapping behavior is linearly proportional to the Stokes layer thickness, δ(AC) ~ O((ν/ω)(1/2)). We show that steady streaming in microfluidic eddies can be a flexible and versatile method for noncontact microparticle trapping, and hence we call this class of devices "hydrodynamic tweezers".

References

YearCitations