IOSR Journal of Mechanical and Civil Engineering · 2013 · 30 citations · 1 references
EngineeringCivil EngineeringBuilding StructuresStructural AnalysisStructural EngineeringBuilding ConstructionSteel StructuresStructural DesignStructural MechanicsStructural Performance AnalysisStructural Response AnalysisBuilding Seismic ResponseComparative Case Study DesignSeismic AnalysisSteel Frame Seismic ResponseSteel Frame Structures
Long Span, Column free structures are the most essential in any type of industrial structures and Pre Engineered Buildings (PEB) fulfill this requirement along with reduced time and cost as compared to conventional structures. The present work involves the comparative study of static and dynamic analysis and design of Pre Engineered Buildings (PEB) and Conventional steel frames. Design of the structure is being done in Staad Pro software and the same is then compared with conventional type, in terms of weight which in turn reduces the cost. Three examples have been taken for the study. Comparison of Pre Engineered Buildings (PEB) and Conventional steel frames is done in two examples and in the third example, longer span Pre Engineered Building structure is taken for the study. In the present work, Pre Engineered Buildings (PEB) and Conventional steel frames structure is designed for dynamic forces, which includes wind forces and seismic forces. Wind analysis has been done manually as per IS 875 (Part III) -1987 and seismic analysis has been carried out as per IS 1893 (2002).
1
Performance of metal buildings in high winds
Dale C. Perry, M. Asce, J.R. McDonald et al. · Journal of Wind Engineering and Industrial Aerodynamics · 1990 · 14 citations