Analytical Chemistry · 2014 · 59 citations · 37 references
Natural SciencesBiochemistryToxicologyAnalytical ChemistryAnalytical ToxicologyMass Spectrometric AnalysisAnalytical ChromatographyBioanalytical ChemistryBioanalytical Method ValidationChromatographyInstrumental AnalysisMass SpectrometryElectrospray IonizationIsotope DilutionIsotope Dilution AnalysisIsotope Dilution Mass SpectrometryLiquid Chromatography-mass SpectrometryProtein PrecipitationSelected Reaction MonitoringStable Isotope Dilution Analysis
This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 μL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100-50.0 ng/mL for GB- and VR-Tyr and 0.250-50.0 ng/mL for GA-, GD-, GF-, and VX/VM-Tyr (R(2) ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA-, GB-, GD-, GF-, VR-, and VX/VM-Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence.
37
A new and rapid colorimetric determination of acetylcholinesterase activity
George L. Ellman, K. Diane Courtney, Valentino Andres et al. · Biochemical Pharmacology · 1961 · 26.9K citations
Quality assurance of chemical measurements
J.K. Taylor, Roy L. Tranter · Analytica Chimica Acta · 1989 · 689 citations
Improved determination of acetylcholinesterase activity in human whole blood
Franz Worek, Ulrike Mast, Daniela Kiderlen et al. · Clinica Chimica Acta · 1999 · 544 citations
Quality Assurance of Chemical Measurements
James P. Lodge · Atmospheric Environment (1967) · 1988 · 518 citations
Sarin poisoning in Matsumoto, Japan
N Yanagisawa, Hiroshi Morita, Tamie Nakajima et al. · The Lancet · 1995 · 314 citations