OBJECTIVES: This study aimed to: understand the effect that high intensity noise associated with drilling (during otological surgery) has on hearing in the contralateral ear; determine the nature of hearing loss, if any, by establishing whether it is temporary or persistent; and examine the association between hearing loss and various drill parameters. METHODS: A prospective clinical study was carried out at a tertiary centre. Thirty patients with unilateral cholesteatoma and normal contralateral hearing were included. Patients were evaluated pre-operatively and for five days following surgery using high frequency pure tone audiometry, and low and high frequency transient evoked and distortion product otoacoustic emission testing. RESULTS: The findings revealed statistically significant changes in distortion product otoacoustic emissions at high frequencies (p = 0.016), and in transient evoked otoacoustic emissions at both low and high frequencies (p = 0.035 and 0.021, respectively). There was a higher statistical association between otoacoustic emission changes and cutting burrs compared with diamond burrs. CONCLUSION: Drilling during mastoid surgery poses a threat to hearing in the contralateral ear due to noise and vibration conducted transcranially.
16
Anatomical correlates of impulse noise-induced mechanical damage in the cochlea
Roger P. Hamernik, George Turrentine, M. Roberto et al. · Hearing Research · 1984 · 178 citations
Drill-Generated Noise Levels in ear Surgery
P. Kylén, Stig Arlinger · Acta Oto-Laryngologica · 1976 · 89 citations
Medicine, Otolaryngology, Surgery +11