New England Journal of Medicine · 1993 · 430 citations · 33 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyAnticoagulant TherapyAntithrombotic TherapyCardiac Valve SurgeryHeart FailureThrombosisThrombosis PreventionAnticoagulation For Prosthetic ValvesBioprosthetic Heart ValvesBioprosthetic Valve ProsthesesDurability Of Bioprosthetic ValvesMechanical Valve ProsthesesPhysiological DeteriorationProsthetic Valve ManagementValves
BACKGROUND: Mechanical heart valves are durable but thrombogenic, and their use requires that the patient receive anticoagulants. In contrast, bioprosthetic valves are less thrombogenic, but they have limited durability because of tissue deterioration. METHODS: To compare the outcomes of patients who receive these two types of valves, we randomly assigned 575 men scheduled to undergo aortic-valve or mitral-valve replacement to receive either a mechanical or a bioprosthetic valve. The primary end points were death from any cause and any valve-related complication. RESULTS: During an average follow-up of 11 years, there was no difference between the two groups in the probability of death from any cause (11-year probability for mechanical valves, 0.57; for bioprostheses, 0.62; P = 0.57) or in the probability of any valve-related complication (0.65 and 0.69, respectively; P = 0.39). There was a much higher rate of structural valve failure among patients who received bioprosthetic valves (11-year probability, 0.15 for the aortic valves and 0.36 for the mitral valves) than among those who received mechanical valves (no valve failures; P < 0.001). However, this difference was offset by a higher rate of bleeding complications among patients with mechanical valves than among those with bioprosthetic valves (11-year probability, 0.42 and 0.26, respectively; P < 0.001) and by a greater frequency of peri-prosthetic valvular regurgitation among patients with mechanical mitral valves than among those with mitral bioprostheses (11-year probability, 0.17 and 0.09, respectively; P = 0.05). CONCLUSIONS: After 11 years, the rates of survival and freedom from all valve-related complications were similar for patients who received mechanical heart valves and those who received bioprosthetic heart valves. However, structural failure was observed only with the bioprosthetic valves, whereas bleeding complications were more frequent among patients who received mechanical valves.
33
The Statistical Analysis of Failure Time Data
John P. Klein · Technometrics · 1982 · 2.2K citations
Albert Starr, M. Lowell Edwards · Annals of Surgery · 1961 · 670 citations · Full text
Twelve-Year Comparison of a Bjork–Shiley Mechanical Heart Valve with Porcine Bioprostheses
P Bloomfield, D J Wheatley, R.J. Prescott et al. · New England Journal of Medicine · 1991 · 432 citations · Full text
Medicine, Cardiology, Surgery +14
PARTIAL AND COMPLETE PROSTHESES IN AORTIC INSUFFICIENCY
Dwight E. Harken, Harry S. Soroff, Warren J. Taylor et al. · Journal of Thoracic and Cardiovascular Surgery · 1960 · 404 citations
Medicine, Cardiology, Surgery +10