2009 · 17 citations · 3 references
EngineeringAerospace EngineeringMechanical EngineeringAerodynamicsCombustionFluid DynamicsCombustion FundamentalsNozzle FlowSupersonic AerodynamicsCorner EffectsFlight ConditionsIsolator DesignIsolator Flow DynamicsIsolator SystemsMach NumberSupersonic CombustionSupersonic Nozzles
An axisymmetric flowpath has been developed for the AFRL/RZAS direct-connect supersonic combustion facility to explore the benefits in operability associated with the reduction of corner boundary layer effects found in rectangular flowpaths. Axisymmetric facility nozzles and isolators have been designed, fabricated, installed and calibrated for free stream flight conditions between Mach 3.5 and 5.0. Flow field surveys have been conducted, utilizing a radially traversing probe, to characterize flow conditions exiting the facility nozzle and isolators. The close overlap of all survey data confirms the symmetric nature of the flow exiting the isolator sections. A back pressure valve, installed downstream of the isolator sections, was used to simulate combustion-induced pressure rise and characterize the performance of two different isolator geometries. The shock-holding performance of the constant divergence isolator has shown to be marginally better than the geometry having a mixture of constant area and divergence. Future work in this area will include comparison of simulated combustion valve induced and combustion induced pressure rise data with the Waltrup-Billig correlation.
3
Structure of Shock Waves in Cylindrical Ducts
P. J. Waltrup, F. S. Billig · AIAA Journal · 1973 · 329 citations