Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · 2013 · 25 citations · 29 references
MedicineCardiologySurgeryCardiothoracic SurgeryRadiographic AnatomyVascular SurgeryAortic DiseaseAortic ImagingAortic SurgeryAortic Valve DiseaseAortic Root AnatomyAortic Valve ImagingEllipsoidsElliptical StructureTomographic Anatomy
OBJECTIVE: A full geometric annuloplasty ring could facilitate aortic valve repair. The purpose of this report was to document the design of such a ring using mathematical analyses of normal human aortic valve computed tomographic angiograms. METHODS: One-millimeter axial slices of high-resolution computed tomographic angiograms from 11 normal aortic roots were used to generate high-density x, y, and z coordinates of valve structures in Mathematica. Three-dimensional least squares regression analyses of leaflet-sinus coordinates were used to assess geometry of aortic valve and root structures. RESULTS: Normal valve geometry could be represented as three leaflet-sinus general ellipsoids nested within an elliptical aortic root. Minor-major diameter ratio of the valve base was 0.60 ± 0.07, and elliptical geometry extended vertically up the commissures. By contrast, leaflet-sinus horizontal circumferences were fairly circular (diameter ratios, 0.82-0.87), and the left coronary/noncoronary commissural post was located at the posterior base minor diameter-circumference junction, with the center of the right coronary leaflet opposite. Post location on the circumference was symmetrical, with a deviation of only ±2% to ±3% from 33.3% symmetry. Commissural posts flared outward by 5 to 10 degrees, and leaflet areas were statistically equivalent (P > 0.10). From end diastole to midsystole, the aortic root became less elliptical (diameter ratio increased by 0.15), but root area expanded minimally (less than +5%). A one-piece rigid annuloplasty ring was designed with 2:3 base ellipticality, three 10-degree outwardly flaring symmetrical posts, and post height = base circumference/2π. CONCLUSIONS: A three-dimensional aortic annuloplasty ring was designed that could prove useful for enhancing applicability and stability of aortic valve repair.
29
Karl E. Hammermeister, Gulshan K. Sethi, William G. Henderson et al. · Journal of the American College of Cardiology · 2000 · 1.1K citations
Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve
Diana Aicher, Takashi Kunihara, Omar Abou Issa et al. · Circulation · 2011 · 369 citations · Full text
Medicine, Cardiology, Surgery +14