Otology & Neurotology · 2014 · 31 citations · 16 references
Health ProfessionsAudiologyOtolaryngologyCochlear ImplantsHearing AssessmentHearing ScienceCochlear Implant RehabilitationCochlear ImplantationElectrode PlacementPediatric Cochlear ImplantationPediatric Cochlear ImplantsSurgical ImplantationCochlear Electrode ArraysCochlear ElectrodesCochlear Implant Electrode ArraysElectrode Array PlacementPerimodiolar Electrode ArraysPerimodiolar Electrode PlacementPerimodiolar ElectrodesPsychophysical Thresholds
OBJECTIVE: Perimodiolar electrode arrays were developed to improve stimulation of specific neuronal populations and to decrease power consumption; however, they can damage the cochlear structure. We examined and compared psychophysical parameters of perimodiolar and lateral-type electrode arrays in patients who received a different type of bilateral cochlear implant (CI) in each ear. STUDY DESIGN: Retrospective analysis. SETTING: Tertiary referral center. PATIENTS: Eight child patients (three males, five females) received a different CI in each ear (perimodiolar array and lateral array). They received the CIs sequentially (n = 7) or simultaneously (n = 1). INTERVENTIONS: Diagnostic, therapeutic, and rehabilitative. MAIN OUTCOME MEASURES: Electrically evoked compound action potential, threshold level, comfort level, and dynamic range (DR) of the basal, mid, and apical electrodes were compared. We also surveyed battery consumption for each device. RESULTS: Electrically evoked compound action potential threshold, threshold level, and comfort level were lower for the perimodiolar-type electrode array than for the lateral-type electrode array in most patients. However, the DR for the perimodiolar array was narrower than for the lateral array. For most patients, there was little difference in battery life. CONCLUSION: Although the level of electrical energy required for auditory stimulation seems to be lower for the perimodiolar electrode array than for the laterally placed array, the DR was wider and the amount of battery consumption was similar. The electrode array should be chosen by considering various patient factors, such as residual hearing.
16
Cochlear view: Postoperative radiography for cochlear implantation
Jian Xu, Sihua Xu, Lawrence T. Cohen et al. · American Journal of Otolaryngology · 2000 · 298 citations
Medicine, Otolaryngology, Surgery +16
Michelle L. Hughes, Paul J. Abbas · The Journal of the Acoustical Society of America · 2006 · 116 citations