Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans

Mohammad Seyyedi, Joseph B. Nadol

Otology & Neurotology · 2014 · 201 citations · 34 references

DOIFull text

Open access

Concepts

TL;DR

Cochlear implant electrodes, though generally considered biocompatible, can provoke chronic inflammation, extrusion, and device failure, with inflammatory responses typically more pronounced near the cochleostomy due to insertion trauma. This study aimed to evaluate the types and degrees of tissue response adjacent to multichannel cochlear implant electrodes. The authors examined 28 temporal bones from 21 subjects, scoring eosinophil, lymphocyte, giant cell, bone, and fibrosis reactions on a 0–3 scale at three 1‑mm segments along each electrode and compared the scores using the Wilcoxon test. Granulomatous reactions were present in 96.4% of bones, eosinophil infiltration in 25% suggesting an allergic component, and the inflammatory response was significantly greater at the basal turn near the cochleostomy than distally.

Abstract

This study evaluates the types and degrees of tissue response adjacent to the electrode of multichannel cochlear implants.Cochlear implant electrodes have been classified as biocompatible prostheses. Nevertheless, in some reports, electrode extrusion, chronic inflammation, and even soft failure of the implant system have been attributed to a tissue response to the electrode.All celloidin-embedded temporal bones with multichannel cochlear implants from the temporal bone collection of the Massachusetts Eye and Ear Infirmary were included in the study. A total of 28 temporal bones from 21 subjects were identified and processed for histology. The severity of cellular response including eosinophil and lymphocytic infiltration, giant cell reaction, new bone formation, and fibrosis were scored on a scale from 0 to 3 at three 1-mm segments along the electrode: first 1 mm at the cochleostomy, last 1 mm from the tip of the electrode, and midway between these proximal and distal segments. The values were compared using the Wilcoxon test.A granulomatous reaction to the electrode was observed in 27 (96.4%) temporal bones. Eosinophil infiltration was observed in 7 (25%) temporal bones, suggesting an allergic reaction. The Inflammatory response to the electrode was significantly greater at the basal turn of cochlea close to the cochleostomy (p < 0.05) than distal to it.An inflammatory response is common after cochlear implantation, and it is more robust at the cochleostomy than distal to it, suggesting the role of trauma of insertion as a contributing factor.

References

34