Clinical Chemistry and Laboratory Medicine (CCLM) · 2014 · 29 citations · 10 references
PharmacyBiochemistryHematologyAnalytical ChemistryGood Laboratory PracticeHematology PhysiologyAnalytical Method ValidationBioanalytical Method ValidationClinical HematologyAnalytical Methods DevelopmentHematological AnalysisHemoglobin LevelsHemolysis AssaysRed Blood Cell Hemoglobin ConcentrationRed Blood Cell HemolysisReference Method ComparisonReference Method Validation
BACKGROUND: Hemolysis is the main cause of non-quality samples in clinical laboratories, producing the highest percentage of rejections in the external assurance programs of preanalytical quality. The objective was to: 1) study the agreement between the detection methods and quantification of hemolysis; 2) establish comparable hemolysis interference limits for a series of tests and analytical methods; and 3) study the preanalytical variables which most influence hemolysis production. METHODS: Different hemoglobin concentration standards were prepared using the reference method. Agreement was studied between automated methods [hemolytic indexes (HI)] and reference method, as well as the interference according to hemolysis degree in various biochemical tests was measured. Preanalytical variables which could influence hemolysis production were studied: type of extraction, type of tubes, transport time, temperature and centrifugation conditions. RESULTS: Good agreement was obtained between hemoglobin concentrations measured using the reference method and HI, for the most of studied analyzers, particularly those giving quantitative HI. The hemolysis interference cut-off points obtained for the majority of tests studied (except LDH, K) are dependent on the method/analyzer utilized. Furthermore, discrepancies have been observed between interference limits recommended by the manufacturer. The preanalytical variables which produce a lower percentage of hemolysis rejections were: centrifugation at the extraction site, the use of lower volume tubes and a transport time under 15 min at room temperature. CONCLUSIONS: The setting of interference limits (cut-off) for each used test/method, and the study of preanalytical variability will assist to the results harmonization for this quality indicator.
10
Ana-Maria Šimundić, Nora Nikolac, Valentina Ivankovic et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2009 · 114 citations · Full text
María Antonia Llopis, Glòria Trujillo, Ma Isabel Llovet et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2011 · 63 citations