Runoff Curve Number Method: Examination of the Initial Abstraction Ratio

Donald E. Woodward, Richard H. Hawkins, Ruiyun Jiang, Allen T. Hjelmfelt, Joseph A. Van Mullem, Quan D. Quan

2003 · 337 citations · 3 references

Concepts

Abstract

The Initial Abstraction ratio (Ia/S, or λ) in the Curve Number (CN) method was assumed in its original development to have a value of 0.20. Using event rainfall-runoff data from several hundred plots this assumption is investigated, and λ, values determined by two different methods. Results indicate a λ value of about 0.05 gives a better fit to the data and would be more appropriate for use in runoff calculations. The effects of this change are shown in terms of calculated runoff depth and hydrograph peaks, CN definition, and in soil moisture accounting. The effect of using λ=0.05 in place of the customary 0.20 is felt mainly in calculations that involve either lower rainfall depths or lower CNs.

References

3