IEEJ Transactions on Industry Applications · 2014 · 14 citations · 11 references
EngineeringElectrical EngineeringElectric MachinesElectromagneticsPower ElectronicsElectric DrivesElectric MotorsLosses In Electric MachinesPermanent Magnet MachinesPermanent MagnetsSynchronous MachinesEddy Current LossesInterior Permanent Magnet MachinesInterior Permanent Magnet Synchronous MachinesIron LossesPermanent Magnet MotorsPermanent Magnet Synchronous MachinesPermanent Magnet Synchronous MotorsThird Harmonic Injection
This paper describes the influence of the PWM inverter harmonic loss and vibration on the concentrated winding interior permanent magnet synchronous motor (IPMSM) characteristics by using a finite element method (FEM) analysis and several measurements. The PWM inverter harmonic mainly caused an increase of eddy current losses in the magnetic steel sheet and the permanent magnet. In addition, the IPMSM with the two-phase modulation inverter has a higher radial electromagnetic force than the IPMSM with the third-harmonic-injection modulation inverter.
11
Effects of slot combination on acoustic noise from induction motors
Takashi Kobayashi, Fumio Tajima, M. Ito et al. · IEEE Transactions on Magnetics · 1997 · 70 citations