Expedient Microdetermination of Itraconazole and Hydroxyitraconazole in Plasma by High-Performance Liquid Chromatography With Fluorescence Detection

22

Citations

5

References

2001

Year

Abstract

The authors describe a useful and rapid micromethod for the analysis of itraconazole (ITZ) and its active metabolite hydroxyitraconazole (HIT) in human plasma. After a simple deproteinization of 100 microL plasma with acetonitrile, the drug, its metabolite, and an internal standard (IS, ketoconazole) were separated on an 8 mm x 10 cm NovaPak (Waters Associates; Milford, MA) C(18) 4-microm particle-size radial compression cartridge. The compounds of interest were detected using a fluorescence detector with the excitation wavelength set at 260 nm and the emission at 365 nm. The mobile phase consisted of 420 mL water adjusted to a pH of 2.5 with phosphoric acid, 580 mL acetonitrile, and 100 microL triethylamine, which was delivered at a flow rate of 3.0 mL/min. This expedient and rugged method is being used to monitor therapeutic levels in bone marrow transplant recipients who are taking the drug for prophylaxis.