Journal of research of the National Bureau of Standards · 1957 · 20 citations · 0 references
EngineeringCivil EngineeringElectrical EngineeringBridge EngineeringInstrumentationStructural EngineeringBridge Condition AssessmentBridge ConstructionBridge DesignBridge Structural AnalysisAccuracyBolometric MagnitudeBridge CircuitsBridge Methods In Electrical MeasurementBridge ReliabilityLoad RatingStructural Rating
Un t il rece ntly, the most acc urate mi crowa ve power m eas ure ments of the bolometri c t ype have required t he use of a manua l d-c bridge. A self-ba lan cin g d-c bridge h as bee n d eveloped t hat preserves t he inheren t accuracy of t he m a nua l bridge, extends the d y namic range of operation, and g reatly simplifies t he operating procedure. A general d esc rip t. ion of the equi pment and ope rating tec hniques is giv en, followed b.v it co mprehensiv e s urvey of t he so urces of error accompanyin g t Ile m ethod a nd t he accuracy ac hieved .