Infusion Versus Bolus of an Ultrasound Contrast Agent

Jean-Michel Corréas, Peter N. Burns, Xiaoming Lai, Xiuling Qi

Investigative Radiology · 2000 · 72 citations · 14 references

Concepts

Abstract

RATIONALE AND OBJECTIVES: To determine the efficacy of an ultrasound contrast agent infusion using Doppler intensitometry estimation of backscatter enhancement in blood. METHODS: Multiple intravenous injections of BR1 (SonoVue) were performed in chronic dog studies, using bolus (0.05-2 mL) and infusion (3-40 mL/h during 6 minutes) administration. The pulsed Doppler signal from the femoral artery was recorded and analyzed for mean Doppler power and integrated fractional enhancement. RESULTS: For bolus injection, time-intensity curves exhibited a rapid first pass (peak 30 dB for 0.45 mL) followed by a slower washout. Integrated fractional enhancement exhibited a linear relation with the dose (R2 = 0.99). For infusion administration, peak enhancement increased with the infusion rate from 8 to 22 dB. At rates exceeding 30 mL/h, the enhancement was stable with a plateau-like pattern. CONCLUSIONS: Infusion of BR1 is easily achieved and allows the duration of enhancement to be increased as long as desired. Stable enhancement is obtained for rates greater than 30 mL/h.

References

14