Evaluation of the 9-kW(e) dish/Stirling system of Schlaich Bergermann und Partner using the proposed IEA dish/Stirling performance analysis guidelines

W. Schiel, Axel Schweitzer, W.B. Stine

Intersociety Energy Conversion Engineering Conference · 1994 · 14 citations · 1 references

Concepts

Abstract

The parabolic dish system with a Stirling engine at the focus is the most efficient of all solar electric power plants, in converting solar radiation into electric energy. One of the most mature systems of this type has been developed by Schlaich Bergermann und Partner (SBP) from Stuttgart, Germany. This 9 kWe system is approaching commercialization, with three currently being operated at the Plataforma Solar Test facility in Almeria, Spain. As of May 1994, more than 1 2,000 operating hours have been accumulated. Guidelines on DisWStirling performance evaluation, as proposed to the International Energy Agency (IEA)' are used to evaluate the performance of the SBP 9kW, system. Normalized performance is evaluated and extrapolated to the rated operating condition. In addition, data from different engine tests are presented to validate linear extrapolation of engine cooling water temperature for test data normalization. A similar correlation for the engine high temperature set point is presented from engine test data.

References

1