Analytical Chemistry · 2014 · 126 citations · 25 references
Life SciencesBiochemistryChemistryAnalytical ChemistryMass Spectrometric AnalysisMetabolomicsMass SpectrometryMass Spectrometry Data AnalysisMass Spectrometry-based MetabolomicsMetabolite IdentificationMetabolite QuantificationMetabolomics Data AnalysisAutomated Peak PickingChemical DerivatizationDerivatizationDifferential Metabolite AnalysisMass Spectral IdentificationMetabolite Data ProcessingMetabolomics Data ProcessingPeak Picking
A chemical isotope labeling metabolomics platform tags metabolites sharing a functional group with a mass tag and analyzes them by LC‑MS. The authors aim to enable quantitative metabolomics across sample groups by automating data processing for this labeling platform. IsoMS automatically extracts, pairs, filters, and quantifies peak pairs from LC‑MS data, aligns them across samples, and outputs a CSV of metabolite ratios relative to a control. IsoMS accurately detected labeled metabolites, identified 2,044 peak pairs in human urine with a 4.4 % false‑positive rate, and is freely available for non‑commercial use.
A chemical isotope labeling or isotope coded derivatization (ICD) metabolomics platform uses a chemical derivatization method to introduce a mass tag to all of the metabolites having a common functional group (e.g., amine), followed by LC-MS analysis of the labeled metabolites. To apply this platform to metabolomics studies involving quantitative analysis of different groups of samples, automated data processing is required. Herein, we report a data processing method based on the use of a mass spectral feature unique to the chemical labeling approach, i.e., any differential-isotope-labeled metabolites are detected as peak pairs with a fixed mass difference in a mass spectrum. A software tool, IsoMS, has been developed to process the raw data generated from one or multiple LC-MS runs by peak picking, peak pairing, peak-pair filtering, and peak-pair intensity ratio calculation. The same peak pairs detected from multiple samples are then aligned to produce a CSV file that contains the metabolite information and peak ratios relative to a control (e.g., a pooled sample). This file can be readily exported for further data and statistical analysis, which is illustrated in an example of comparing the metabolomes of human urine samples collected before and after drinking coffee. To demonstrate that this method is reliable for data processing, five 13C2-/12C2-dansyl labeled metabolite standards were analyzed by LC-MS. IsoMS was able to detect these metabolites correctly. In addition, in the analysis of a 13C2-/12C2-dansyl labeled human urine, IsoMS detected 2044 peak pairs, and manual inspection of these peak pairs found 90 false peak pairs, representing a false positive rate of 4.4%. IsoMS for Windows running R is freely available for noncommercial use from www.mycompoundid.org/IsoMS.
25
HMDB: the Human Metabolome Database
David S. Wishart, Dorit Tzur, Craig Knox et al. · Nucleic Acids Research · 2007 · 3.3K citations · Full text