Micropaleontology · 1996 · 106 citations · 6 references
Natural SciencesPaleontologyMicropaleontologyPaleobiologyPaleoclimatologyQuaternary MicropaleontologyQuaternary PaleoecologyZooarchaeological QuantificationMicropaleontological AnalysisMicropaleontological PaleoecologyQuantitative MicropaleontologySpecies Abundance Analysis
A quantitative preparation method is described in order to enable high precision coccoliths analysis with the scanning electron microscope (SEM). This technique is fast and easy to apply and very thorough in the counting procedure. An equivalent basis for the comparison of datasets from sediments and water column is accomplished. INTRODUCTION There is a current demand to improve micropaleontological investigations in order to calculate absolute abundances of microfossils. A high precision counting is required for the comparison with other planktic groups as in synoptic studies (Samtleben et al. 1995) or for detailed understanding of coccoliths assemblages of Late Quaternary to Recent age (Andruleit 1995). In the past few years an increasing number of new preparation techniques for coccoliths counting have been published aiming for quantitative analysis (Baumann 1990; Beaufort 1991; Henriksson 1993; Okada 1992; Samtleben and Schroder 1992; Wei 1988). However, each method has its certain restrictions. For example, extensive processing may cause alterations of the assemblages, or studies using the light microscope may have taxonomic problems. Also, a corresponding method is needed for comparison of coccoliths fluxes obtained from sediment trap investigations with coccoliths accumulations in the sediments. The presented method combines techniques from different applications to improve quantitative coccoliths analysis and allows the comparison of coccoliths assemblages from differing datasets. PROCEDURE The whole procedure is summarized in text-figure 1. Part A: Step 1: Freeze dry the sediment sample Step 2: Weigh about 0.05 to 0.5g of the freeze-dried sediment on a high precision balance (the amount depends on the coccoliths content). Step 3: Dilute the sample with about 10ml of water (e.g. carbonate saturated tap-water or demineralized water buffered by ammonia with pH=9). Step 4: Ultrasonicate the suspension for about 15 sec. If there are still small lumps visible repeat the ultrasonic treatment for another 5 to 10 sec. Step 5: Fill the suspension up to about half a liter or more and homogenize by thorough shaking. Part B: Step 6: Split the diluted suspension by using a rotary splitter at about 40 to 50 rotations per minute. To minimize splitting errors mix the opposite sample splits together after each splitting round. Op imal splits are mostly accomplished with the 1/256 fraction (i.e. split factor=256). Depending on the amount of sediment or coccoliths content other split fractions may be more suitable. Part C: Step 7: Filter the split fraction through Millipore filter (0.45pm pore width) by means of a vacuum pump. Step 8: Dry the filter for about six to twelve hours at 40?C. Step 9: Cut a small piece (about one cm2) out of the filter and prepare it for the SEM Step 10: Investigate species composition and abundances on measured transects. The numbers of coccoliths per gram dry sediment can then be calculated as follows: Coccoliths [no.g] = F*C*S A*W F = filter area [mm2] C = number of counted coccoliths A = investigated area [mm2] W = weight of sample [g] S = split factor Reproducibility The whole procedure was already applied to about 150 sediment samples of Holocene age from the northern North Atlantic (Andruleit 1995). The reproducibility of the counts mainly depends on 1) the homogeneity of the particle distribution on the filter and 2) the precision of the splitting. 1) Standard counts were performed on areas of only 0.05mm2 in size with a magnification of 3000 to 5000. The homogeneity of the particle distribution is documented by the comparison of the counts of two different areas of the same examined filter micropaleontology, vol. 42, no. 4, pp. 403-406, text-figures 1-3, 1996 403 This content downloaded from 157.55.39.59 on Sat, 15 Oct 2016 04:34:58 UTC All use subject to http://about.jstor.org/terms Harald Andruleit: A filtration techniquefor quantitative studies of coccoliths
6