Foot & Ankle International · 1995 · 39 citations · 11 references
MedicineOrthopaedic SurgerySurgeryGeneral SurgeryOrthopedicsReconstructive SurgeryHallux ValgusInternal FixationDistal Chevron OsteotomyFollow-up DurationHallux Valgus Joint DeformityHallux Valgus ManagementInternal Fixation Devices
The Chevron osteotomy has become popular for the treatment of hallux valgus deformity. Displacement of the osteotomy is a known complication. Many methods of internal fixation have previously been reported to prevent the displacement and each has inherent advantages and disadvantages. An alternative method of fixation, utilizing absorbable polydioxanon pins, is presented in this article. Between April 1989 and April 1990, 71 procedures were performed on 50 patients. At 1-year follow-up, there were no complications or infections. Review of the osteotomy after surgery and at 1 year revealed no fractures or displacements, and no pins required removal. Internal fixation utilizing absorbable polydioxanon pins appears to have significant benefits when compared with metallic fixation.
11
Chevron Osteotomy Fixed with Absorbable Polyglycolide Pins
Eero Hirvensalo, Ole Böstman, Pertti Törmälä et al. · Foot & Ankle · 1991 · 102 citations